Do you have questions about this item or would you like to order it?
Features:
- Automatic brightness control (ABC)
- Bright source protection (BSP)
General technical data according to specification:
Type name | Gen. III (HP1850‑I) |
Tube diameter | 37mm |
Phosphor | P22/P43 |
Input window | Glass |
Output window | Inverting fibre-optic |
Type of contacts | Strip contacts |
Specification | On request |
Drawing | On request |
Parameters | minimum | typical | maximum | unit |
FOM (performance value of a tube) | 1836 | |||
Limiting resolution | 68 | lp/mm | ||
S/N (signal to noise ratio) at 108μlx | 27 | |||
Cathode sensitivity at 2850K | 2000 | μA/lm | ||
Luminance, gain at 2×10-6 fc | 40000 | 70000 | fl/fc | |
MTTF (operational life) | 10000 | hours | ||
IR wavelength operating range | 550 | 900 | nm | |
Radiant sensitivity at 830nm | 210 | mA/W | ||
Image inversion | 178° | 180° | 181° | |
MTF at 2,5 lp/mm | % | |||
MTF at 7,5 lp/mm | % | |||
MTF at 15 lp/mm | % | |||
MTF at 25 lp/mm | % | |||
MTF at 30 lp/mm | % | |||
Useful cathode diameter | 17,5 | mm | ||
Output uniformity at 2850K | ||||
HALO size (illumination spot 0,2mm) | 1,0 | mm | ||
Maximum output brightness | 2 | 17 | cd/m2 | |
E.B.I. (equivalent background illumination) | μlx | |||
Shock resistance | 500 | G | ||
Weight | 85 | gram |
Maximum number of spots according to specification:
Spots diameter in micrometers | zone 1 (d=5,6mm) |
zone 2 (d=5,6mm-14,7mm) |
zone 3 (d=14,7mm-17,5mm) |
> 380 | 0 | 0 | 0 |
300 − 380 | 0 | 0 | 0 |
230 − 300 | 0 | 0 | 0 |
150 − 230 | 0 | 1 | 2 |
75 − 150 | 0 | 2 | 2 |
75 | minimal | minimal | minimal |
All regular articles have a 14 days right of return and 5 years guarantee, with a service address in the Germany! Except Commercial Grade models, these devices are covered by the general 2 years guarantee.